ZDLRA, Patch/Update the Recovery Appliance

The process of patch ZDLRA is not complicated, but it is important to be aware of some details. The most important is from where you are until where you want to go. This is crucial because it will define what commands you will need to execute.

If you read the previous post about the process, you can notice that I was running the ZDLRA 12.2 version, and forwarded to 19.2 version. In that case, I needed to use the upgrade path since I was changing the major release and the racli commands had the “upgrade” parameter.

In this post I will show how to do a simple update (or patch apply) for ZDLRA, this means that I will remain inside the same major release for recovery appliance library. Some steps and checks are the same.

Whatever you need to do (patch or upgrade), the startup point it is the note 1927416.1 that cover the supported versions for ZDLRA. There it is possible to find all the supported versions for the recovery appliance library as well as the Exadata versions. Please, not upgrade the Exadata stack with a version that is not listed on this page.

Click here to read more…

Exadata and ZDLRA, Patch Exadata Stack

The process to patch Exadata stack and software changed in the last years and it became easier. Now, with patchmgr to be used for all (database servers, storage cells, and switches) the process is much easier to control the steps. Here I will show the steps that are involved in this process.

Independent if it is ZDLRA or Exadata, the process for Engineering System is the same. So, this post can be used as a guide for the Exadata patch apply as well. In 2018 I already made a similar process about how to patch/upgrade Exadata to 18c (you can access here) and even made a partial/incomplete post for 12c in 2015.

The process will be very similar and can be done in rolling and non-rolling mode. In the first, the services continue to run and you don’t need to shutdown databases, but will take more time because the patchmgr applies server by server. At the second, you need to shutdown the entire GI and the patch is applied in parallel and will be faster.

Click here to read more…

ZDLRA, Patch the Recovery Appliance

The proceed to patch/upgrade ZDLRA is not complicated, but as usual, some details need to be checked before starting the procedure. Since it is one engineering system based at Exadata, the procedure has one part that (maybe) needs to upgrade this stack too. But, is possible to upgrade just the recovery appliance library.

Whatever if need or no to upgrade the Exadata stack, the upgrade for recovery appliance library is the same. The commands and checks are the same. The procedure described in this post cover the upgrade of the recovery appliance library. For Exadata stack, it is in another post.

Where we are

Before even start the patch/upgrade it is important to know exactly which version you are running. To do this execute the command racli version at you database node:

[root@zeroinsg01 ~]# racli version
Recovery Appliance Version:
        exadata image: 19.2.3.0.0.190621
        rarpm version: ra_automation-12.2.1.1.2.201907-30111072.x86_64
        rdbms version: RDBMS_12.2.0.1.0_LINUX.X64_RELEASE
        transaction  : kadjei_julpsu_ip2
        zdlra version: ZDLRA_12.2.1.1.2.201907_LINUX.X64_RELEASE
[root@zeroinsg01 ~]#

With this, we can discover the ZDLRA version running (12.2.1.1.2.201907 in this case), and the Exadata image version (19.2.3.0.0.190621).

Click here to read more…

Solving MGMTDB errors during 18c GI RU apply

Recently I executed the upgrade of Oracle GI to 19c version, from 18.6.0.0 to 19.5.0.0 version. But one step that was not showed there was that, because of requirements, the GI was upgraded from 18.2.0.0 to 18.6.0.0. This upgrade is a just Release Update (RU) apply and opatchauto command.

But during this upgrade, from 18.2 to 18.6, I faced (more than one time – 5 to be precise) errors during the update because of the MGMTDB errors. I got these errors:

  • ORA-12514, TNS: Listener does not currently know of service requested in connect descriptor
  • ORA-01017: invalid username/password; logon denied
  • MGTCA-1005 : Could not connect to the GIMR.
  • CRS-10407: (:CLSCRED1079:)Credential domain does not exist.

Here I will show how to solve these errors, how to identify if everything was fine and if you can continue. Be careful that it is an example, always open a support SR to identify the source of the error.

Click here to read more…

19c Grid Infrastructure Upgrade

Upgrade GRID infrastructure is one activity that usually is postponed because it involves a sensible area that, when not works, causes big downtime until be fixed. But, in the last versions, it is not a complicated task and if you follow the basic rules, it works without problems.

Here I will show a little example of how to upgrade the GI from 18.6.0 to 19.5. The steps below were executed at Exadata running version 19.2.7.0.0.191012 and GI 18.6.0.0, but can be done in every environment that supports Oracle GI.

Click here to read more…